PS/RHF Cable – PS to RHF Console
See pages 4-6 and 4-22 through 4-25 for remaining RHF console connections.
RUN LIST – PS/RHF CABLE
SIGNAL
PLUG 1X1
COLOR
PLUG 2X1
HF XFMR
1
BLACK
12
HF XFMR
2
RED
15
Gnd
3
SHIELD
CUT
SV6/Inj. H2O
4
BLACK
2
SV6/Inj. H2O
8
WHITE
5
Gnd
9
SHIELD
CUT
FS2/Flow SW
10
BLACK
10
FS2/Flow SW
11
GREEN
13
Gnd
12
SHIELD
CUT
FS1/Flow SW
23
BLACK
7
PS1/Pressure SW
24
BLUE
8
Gnd
25
SHIELD
CUT
S1,S2/Door Intlk
34
BLACK
1
S1,S2/Door Intlk
35
YELLOW
4
Gnd
36
SHIELD
CUT
CR1
28
BROWN
9
Pilot Arc Relay
21
BLACK
11
Gnd
26
SHIELD
CUT
CR2
5
ORANGE
3
6
BLACK
6
Gnd
7
SHIELD
CUT
5
PS End
1X1
2X1
RHF End
Part No.
Length
023764
50 ft (15 m)
023765
75 ft (23 m)
023766
100 ft (30.5 m)
Part No.
Length
023767
150 ft (46 m)
023768
200 ft (61 m)
023769
300 ft (91.5 m)