background image

INSTALLATION

1-98

4-8

HT4001

Instruction Manual

Power Supply Connections (cont.)

PS/RHF Cable – PS to RHF Console

See pages 4-6 and 4-22 through 4-25 for remaining RHF console connections.

RUN LIST – PS/RHF CABLE

SIGNAL

PLUG 1X1

COLOR

PLUG 2X1

HF XFMR

1

BLACK

12

HF XFMR

2

RED

15

Gnd

3

SHIELD

CUT

SV6/Inj. H2O

4

BLACK

2

SV6/Inj. H2O

8

WHITE

5

Gnd

9

SHIELD

CUT

FS2/Flow SW

10

BLACK

10

FS2/Flow SW

11

GREEN

13

Gnd

12

SHIELD

CUT

FS1/Flow SW

23

BLACK

7

PS1/Pressure SW

24

BLUE

8

Gnd

25

SHIELD

CUT

S1,S2/Door Intlk

34

BLACK

1

S1,S2/Door Intlk

35

YELLOW

4

Gnd

36

SHIELD

CUT

CR1

28

BROWN

9

Pilot Arc Relay

21

BLACK

11

Gnd

26

SHIELD

CUT

CR2

5

ORANGE

3

6

BLACK

6

Gnd

7

SHIELD

CUT

5

PS End

1X1

2X1

RHF End

Part No.

Length

023764

50 ft (15 m)

023765

75 ft (23 m)

023766

100 ft (30.5 m)

Part No.

Length

023767

150 ft (46 m)

023768

200 ft (61 m)

023769

300 ft (91.5 m)

Advertising