H401 slave connections (cont.) – Hypertherm HT4001 Plasma Arc Cutting System User Manual
Page 232

APPENDIX A
a-10
HT4001
Instruction Manual
H401 Slave Connections (cont.)
When using the H401 Slave, a positive and negative lead must connect the HT4001 to the H401. Two 25-foot
cables (023136) come with the 077011 kit for this purpose.
Also, an additional positive lead must run from the positive bus bar in the HT4001 power supply to the work table,
and an additional negative lead must run from the negative bus bar in the HT4001 power supply to the cathode
block of the RHF console.
Refer to Fig. a-6.
Positive Lead – HT4001 Power Supply to H401 Power Supply
Negative Lead – HT4001 Power Supply to H401 Power Supply
Positive Lead – HT4001 Power Supply to Work Table
Negative Lead – HT4001 Power Supply to RHF Console
31
32
33
34
Part No.
Length
023136
20 ft (6 m)
023078
25 ft (7.5 m)
023101
30 ft (9 m)
023135
40 ft (12 m)
023079
50 ft (15 m)
Part No.
Length
023124
75 ft (23 m)
023080
100 ft (30.5 m)
023081
150 ft (46 m)
023316
180 ft (55 m)
023188
200 ft (61 m)