INSTALLATION

10-99

4-14

HT4001

Instruction Manual

Power Supply Connections (cont.)

Machine Interface V/C Cable – PS to Machine Interface

Note:

If HT4001 system uses the digital remote V/C unit to set voltage and current, skip this step. The
machine interface V/C cable is used only with the programmable remote.

Before connecting the machine V/C interface cable, see the wiring diagrams in this manual and verify that the
correct plug is attached to the µP control PCB REC6 receptacle.

PS END
SCKT

COLOR

DESCRIPTION

1

Black

Current 5

2

Wht

Current 10

3

Red

Current 20

4

Green

Current 40

5

Orange

Current 80

6

Blue

Current 100

7

White/Black

Current 200

8

Red/Black

Current 400

9

Green/Black

Current 800

10

Shield

Shield

11

Blue/Black

Current ICom

12

Black/White

spare

13

Red/White

spare

14

Green/White

Voltage V1.25

15

Blue/White

Voltage V2.5

16

Black/Red

Voltage V5

17

White/Red

Voltage V10

18

Orange/Red

Voltage V20

19

Blue/Red

Voltage V40

20

Red/Green

Voltage V80

21

Orange/Green

Voltage V100

22

Black/White/Red

Voltage V200

23

White/Black/Red

Voltage VCom

8

PS End

1X7

Part No.

Length

023851

15 ft (4.5 m)

023852

25 ft (7.5 m)

023853

35 ft (10.6 m)

023854

50 ft (15 m)

Part No.

Length

023855

75 ft (23 m)

023856

100 ft (30.5 m)

023903

125 ft (38 m)

023857

150 ft (46 m)

023858

200 ft (61 m)

Advertising