4. Connect leads L1 to U, L2 to V, and L3 to W terminals of TB5 (see Figure c-3). Ensure that all connections are

tight to avoid excessive heating.

5. Connect the ground lead to terminal marked

at TB5 (see Figure c-3).

Figure c-3

Power Cable Connections to TB5

Line Disconnect Switch

Connecting the power cable to the line disconnect switch must conform to national or local electrical codes. This
work should be performed only by qualified, licensed personnel. See Power Requirements and Line Disconnect
Switch
on pages 3-4 and 3-5.

TB5

WARNING

There is line voltage at the filter as soon as the line disconnect switch is ON, even if the circuit breaker
on the HT4001 power supply is OFF. As a common safety practice, ALWAYS verify that the line
disconnect switch is in the OFF position before installing, disconnecting or servicing in this area.