Oxygen, Ht4001 without slave, Pac620 torch – beveling consumables – Hypertherm HT4001 Plasma Arc Cutting System User Manual

Page 117: Mild steel – oxygen plasma

Advertising
background image

5-26

HT4001

Instruction Manual

1-99

HT4001 without Slave

PAC620 Torch – Beveling Consumables

Mild Steel – Oxygen Plasma

Notes:

Minimum O

2

inlet pressure remains at one setting of 120 psi (8.2 bar) for all material thickness.

Minimum N

2

inlet pressure remains at one setting of 150 psi (10.3 bar) for all material thickness.

O

2

flow rate at full scale is 127 scfh (60 l/min) @ 120 psi (8.2 bar) inlet pressure.

N

2

flow rate at full scale is 374 scfh (176 l/min) @ 150 psi (10.3 bar) inlet pressure.

Water chiller pump outlet pressure remains between 175-185 psi (12-12.8 bar) for all material thickness.
Set initial torch height (before piercing) to approximately twice the Torch Standoff distance for the material you
are cutting.

Retaining Cap

120390 (Vect)

120391 (Vesp)

Nozzle

120384 (cw)

120385 (ccw)

Swirl Ring

120460 (cw)

120461 (ccw)

Electrode

340 A

120836

Water Tube – O

2

Bevel

020992

120470 – CE (Vect)
120471 – CE (Vesp)

E

N

G

L

I

S

H

M

E

T

R

I

C

Test Cut Flow

Rate

(N

2

)

&

(O

2

)

(O

2

)

(in)

(mm)

(%)

(%)

(%)

(%)

(in)

(mm)

(ipm)

(mm/min)

1/2

12.7

16

11

85

73

135

340

3/16

5

110

2800

3/4

19.1

16

11

85

73

140

340

3/16

5

85

2160

1

25.4

16

11

85

73

145

340

3/16

5

65

1650

1-1/4

31.8

16

11

85

73

145

340

3/16

5

45

1140

340A

Arc Volts

(V)

Arc

Current

(A)

Torch

Standoff

Travel Speed

Electrode

Material

Thickness

Test Preflow

Rate

Water Flow

Setting

Test Cut Flow

Rate

(N

2

)

&

(O

2

)

(O

2

)

(mm)

(%)

(%)

(%)

(%)

(mm)

(mm/min)

15

16

11

85

73

135

340

5

2570

20

16

11

85

73

140

340

5

2080

25

16

11

85

73

145

340

5

1680

30

16

11

85

73

145

340

5

1280

340A

Arc Volts

(V)

Arc

Current

(A)

Torch Standoff

Travel Speed

Electrode

Material

Thickness

Test Preflow

Rate

Water Flow

Setting

Advertising