H401 slave connections (cont.) – Hypertherm HT4001 Plasma Arc Cutting System User Manual
Page 230
Advertising
H401 Slave Connections (cont.)
Slave Cable – HT4001 Power Supply to H401 Power Supply – Fig. a-5
• Connect the 1X8 end of the slave cable to the 1X8 connector on the HT4001 power supply.
APPENDIX A
4-98
a-8
HT4001
Instruction Manual
30
HT4001 PS
H-401 CURRENT
END 1x8
COLOR
SETPOING END
DESCRIPTION
1
Red
2
Slave/Plasma On
5
Black
1
Slave/Plasma On
10
Drain
–
PE
2
Green
4
200A
6
Black
3
200A
11
Drain
–
PE
3
White
6
400A
7
Black
5
400A
12
Drain
–
PE
4
20
Slave Cable
8
7
Detect
Part No.
Length
123377
25 ft (7,6 m)
1X8
Advertising