Connecting the power -11, Connecting the power – Hypertherm HT4001 Plasma Arc Cutting System User Manual

Page 51

Advertising
background image

Ground
(PE)

L1

L2

L3

CON1

Power
Cable

Strain
Relief

Power Cable to HT4001 Power Supply

To connect the power cable to the 400V CE power supplies (077022 and 077023), refer to
Appendix C. To connect the power cable to the 200/220V power supplies (077002 and
077016), refer to Appendix D. For all other power supplies, use the procedure below.

1. Insert the Power Cable through the Strain Relief located in the rear of the power supply.

2. Connect the power leads to the L1, L2, and L3 terminals of CON1. See Fig. 3-9.

3. Connect the Ground (PE) lead to the stud as shown in Fig. 3-9.

Connecting the Power

16

PRE-INSTALLATION

HT4001

Instruction Manual

3-11

Figure 3-9

Power Cable Connections

WARNING

There is line voltage at the contactors after the line disconnect switch is ON, even if the circuit breaker
on the HT4001 power supply is OFF. As a common safety practice, ALWAYS verify that the line
disconnect switch is in the OFF position before installing,
disconnecting or servicing in these areas.

WARNING

The line disconnect switch must be in the OFF position before making the power cable connections! In
the U.S., use a “lock-out/tag-out” procedure until installation is complete. In other countries, follow
appropriate local or national safety procedures.

Advertising