V T 1 0 0 I n t e r f a c e

4-7

From the Interfaces screen, you may choose from Network, 10/100 Ethernet,
or Supervisory.

Network Screen

The Network port operates in the long-haul or short-haul mode. The Network
screen lets you view and make changes to the Network interface's
configuration as described below. In addition, this screen provides a table that
displays the alarm values for the Network interface.

Figure 4.7

Network Screen

Framing

Selects the framing for the network side of the DSU/CSU.

Values

ESF, D4

Default: ESF

Line Coding

Sets the network side line coding.

Values: B8ZS, AMI
Default: B8ZS

PRM Enable

Lets you establish which performance messaging standard will be employed
to initiate Performance Report Message (PRM) functions. Setting this field to
“Enable” instructs the unit to use ANSI T1.403, which sends a PRM once
every second. Setting this field to “Disable” instructs the unit to use AT&T
TR54016, which provides performance reporting on request only.

Values: Disable, Enable

Learn DS0s on Boot

Determines if the unit will attempt to discover active DS0s (after power-up,
Save and Restart). Active DS0s will then be assigned to the first associated
network service.

Values: Disable, Enable
Default: Disable