V T 1 0 0 I n t e r f a c e

4-21

RFC1315 Trap

When this parameter is set to “Enable,” the unit will send the standard
RFC1315 frame relay DTE circuit state change trap every time a DLCI
changes state, provided at least one destination IP address for trap is
configured in the SNMP configuration.

Values: Disable, Enable
Default: Disable

Rx Invalid Threshold

Number of invalid frames received during a 15-minute interval after which an
Rx invalid alarm will be triggered. A value of “0” (zero) disables this trap.

Values: 0–4294967295
Default: 0

Rx Invalid Alarm

Status of this alarm (OK, Alarmed).

User prompts at the bottom of the Frame Relay Services Details screen are
described in the following table.

Select the “Frame Relay Statistics” prompt to bring up a table (Figure 4.18)
that reports on the status and condition of LMI parameters and on Receive/
Transmit alarms and thresholds. Alarm threshold levels may be changed by
entering a new threshold value in the appropriate field on the Frame Relay
Service Details screen and pressing the “Esc” key.

Prompt

Function

Frame Relay

Statistics

Opens the Frame Relay Statistics screen for the current frame
relay service.

Clear Alarms

Clears all Frame Relay alarms.

Pair Type Details

Opens another Frame Relay Service Details screen that reverses
the service and the pair so that you can view both sides of the
pair.

DLCI Table

Opens the DLCI Table screen, which displays all the DLCIs on
the current service. Refer to DLCI Table Screen on page 4-37 for
more information.