Verilink T1 Access Router (34-00327) Product Manual User Manual

Page 63

Advertising
background image

W e b S e r v e r I n t e r f a c e

3-35

remote unit answers to the discovery frames sent by this unit. The status is
“SOS” if the remote unit is active but the FRAD/Router connected to it is
inactive. The status is “Inactive” in all other cases.

Values: Active, Inactive, SOS
Default: Inactive

Remote DLCI

If the remote unit is a Verilink FSx product, and FrameStart Auto Discovery
is enabled, this displays the DLCI number used on the remote end of this
DLCI.

Values: 16

1023

Default: 0

Remote Unit

If the remote unit is a Verilink FSx product, and FrameStart Auto Discovery
is enabled, this parameter gives the first three digits of the unit ID configured
on the remote end of this DLCI.

Values: 000

999

Default: 000

Remote Unit IP

Address

Displays the IP address of the remote Verilink unit with FrameStart
technology if FrameStart Auto Discovery is enabled.

Round Trip Delay Size

(bytes)

Specifies the frame size (in bytes) of packets making the round-trip. If the
Round Trip Delay Size is not configured, the Frame Relay Details values will
be used.

Round Trip Delay Rate

(secs)

Specifies the rate (in seconds) at which Round Trip Delay packets are sent. If
the Round Trip Delay Rate is not configured, the Frame Relay Details values
will be used.

DLCI Status Table

The bottom portion of the screen displays a table detailing the actual status of
DLCI and alarm threshold information as follows:

Status

If this DLCI is up, the status will be “Active”; otherwise, the status will be
“Inactive.”

Values: Active, Inactive
Default: Inactive

Receiving FECN/

BECN

When a frame is received with congestion bit set, this parameter is set to
“Yes.” It is set back to “No” when a frame is received without congestion bit
set.

Values: Yes, No
Default: No

CIR Threshold

Sets the Tx over CIR alarm threshold. This threshold is the number of bits per
second in excess of CIR during a 15-minute interval. Setting this field to “0”
(zero) disables the alarm.