Verilink T1 Access Router (34-00327) Product Manual User Manual

Page 62

Advertising
background image

3-34

T 1 A c c e s s R o u t e r

Proprietary Traffic

Type

When Protocol Encapsulation is set for “Proprietary,” the Proprietary Traffic
Type parameter defines which protocol is encapsulated.

Values: IP, IPX, Ethertype, None
Default: None

Proprietary Offset

When Protocol Encapsulation is set for “Proprietary,” the Proprietary Offset
parameter defines the number of octets after the frame relay header where the
proprietary traffic type starts.

Values: 0–64
Default: 0

CIR (bps)

If a Committed Information Rate is configured here, its value will be used
instead of the default CIR of the Frame Relay service.

Values: 0–1536000
Default: 0

Be (bps)

If an Excess Burst Rate is configured here, its value will be used instead of
the default excess burst of the Frame Relay service.

Values: 0–1536000
Default: 0

Bc (bps)

If CIR enforcement is configured to “Yes,” the unit will throttle the
committed burst down to this value when frames are received with the BECN
bit set.

Values: 0–1536000
Default: 0

Discard Eligible Flag

If this parameter is set to “Yes” and CIR enforcement is also set to “Yes,” the
unit will set the Discard Eligible (DE) bit for frames sent over CIR.

Values: Yes, No
Default: No

In Band Management

If the unit is to be used as a gateway to reach a remote T1 Access Router
through this DLCI, this parameter should be set to “Yes,” and the remote IP
address and Mask should be configured in the corresponding endpoint.

Values: Yes, No
Default: No

FrameStart Delay

If this parameter is set to “Enable,” the unit will send FrameStart discovery
and delay frames on this DLCI, and will report the state of the remote
Verilink FSx unit. It will also send SOS frames when the FRAD/router
connected to this unit goes inactive.

Values: Enable, Disable
Default: Enable if Auto Discovery is set to “Yes”; Disable otherwise

FrameStart Status

If the remote unit is a Verilink FSx product and FrameStart Auto Discovery is
enabled, the FrameStart Status field will show the status of the remote unit.
The status is “Active” if both the local and remote DLCIs are active and the

Advertising