Internet connection – Wavetronix SmartSensor 105 (SS-105) - User Guide User Manual

Page 40

Advertising
background image

CHAPTER 4 • COMMUNICATION

39

Figure 4.5 – Advanced Modem Settings

˽

Local Modem Settings – The initialization string and auto-find command can be en-

tered in their respective text fields in the Local Modem Settings section. The Restore

Defaults button will return these functions to their default settings. The port number

and baud rate will be automatically detected by SmartSensor Manager, so these set-

tings cannot be changed.

˽

Additional Response Wait Time – By default, SmartSensor Manager waits a few mil-

liseconds to receive a response from the sensor before timing out and displaying a

communication error message. You can add additional milliseconds to the response

wait time to give the program more time to make a connection. Click the Use an addi-

tional: check box to activate the milliseconds text field and enter the number of addi-

tional milliseconds SmartSensor Manager should wait for a response from the sensor.

˽

SmartSensor Network Protocol – These options can be used to identify sensors that

are part of a multi-drop network. The Simple protocol option refers to sensors that are

not part of a multi-drop environment. If the sensor is part of a multi-drop network,

SmartSensor Manager can either auto-detect the multi-drop ID, or you can enter the

four-digit ID. Clicking the Use Multidrop Protocol… Connect Directly to ID: radio

button will activate the text box so you can enter the ID number.

˽

Time Synchronization – Click the check box to have SmartSensor automatically syn-

chronize with the PC clock.

Click the check box near the bottom of the Advanced Connection Settings page to use

the new settings as default. The OK button saves the new settings and the Cancel button

cancels the changes; both buttons return you to the Modem Connection page. The new

settings will be displayed in the message bar at the bottom of the page.

Internet Connection

The Internet (TCP/IP) option will allow you to connect to the SmartSensor using the