Chapter 2: Commissioning the Sunny Boy Control Light

SUNBCL-11:NE

- 17 -

SMA Regelsysteme GmbH

The electricity facilities in buildings supply energy to electric devices with

230 V / 50 Hz (or e.g. 120 V / 60 Hz in the USA). This electricity distribution system is

not optimized for the transmission of high frequency signals (approx. 132 kHz).

Therefore the interference-free communication in this frequency range essentially

depends on the selection of the transmission line between the units and the Sunny

Boy Control Light.

The transmission link should:

use only one phase and

be as short as possible

Pay attention about connecting all devices that transmit and receive data to one

phase or preferably even to the same line. Therefore you should choose a socket for

the Sunny Boy Control Light installed on the same line resp. at least on the same

phase as the device and is as near as possible to its feeding point.

In case the Sunny Boy Control Light and the according devices must be connected

to different phases the installation of a phase coupler can be necessary. Phase

couplers are available from SMA and must be installed on the site by a qualified

technician.

Further information on optimizing the installation is available in chapter 7.2.1

"Transmission Errors".

If there are any other users of Powerline equipment in your neighborhood, you

should have an eye on the device detection and pay special attention to the

according dialogs in order to ensure that you detect your own devices only. Sunny

Boy Control Light can run the device detection automatically if there is no special

interference. All device detection dialogs will be confirmed automatically after 60 sec

and therefore all devices found will be registered. All you have to do after the

automatic device detection is done by Sunny Boy Control Light is to exit the device

detection by pressing the

[[[[

ESC

]]]]

key and confirm the final security dialog with

[[[[

Enter

]]]]

.