Sunny Boy Control Light

Chapter 5: Menu Functions for Configuration

SUNBCL-11:NE

- 51 -

SMA Regelsysteme GmbH

Example DATALITE Display

Telegram (Hex)

Meaning / Display

01 20 1C

Start, Controller-Address, Field Separator

30 41 6B 74 75 65 6C 6C 3A 1C

Power:

31 20 20 20 20 36 35 34 20 57 20 1C

654 W

32 48 65 75 74 65 3A 1C

Today:

33 20 20 20 34 2E 31 36 20 6B 57 68 1C

4.16 kWh

34 47 65 73 61 6D 74 3A 1C

Total:

35 20 20 32 34 31 37 37 20 6B 57 68 1C

24177 kWh

36 44 61 74 75 6D 3° 20 20 25 44 2E 25 4D 2E 25 59 1C

Date:

%D.%M.%Y

37 5A 65 69 74 3A 20 20 20 25 48 3A 25 6D 3A 25 53 1C

Time:

%H:%m:%S

16 0D 01 30 1C

Synchronisation

0D

End (CR)

Example for setting the internal time

at 30/11/1999 14:18:58

Telegramm (Hex)

Meaning

01 7F 1C

Start, Controller-Address, FS

1B 54

Adjust Real-Time-Clock

33

Year 1999: x33 = d51 = d99 + d32 – d80

2B

Month 11: x2B = d43 = d11 + d32

20

No

3E

Day 30: x2E = d62 = d30 + d32

2E

Hour 14: x2E = d46 = d14 + d32

32

Minute 18: x32 = d50 = d18 + d32

5A

Second 58: x5A = d90 = d58 + d32

0D End

Further details are available in the user manual of the display and on the internet

pages of the DATALITE manufacturer (

www.datalite.nl

).