Sunny Boy Control Light

Chapter 7: Appendix

SUNBCL-11:NE

- 74 -

SMA Regelsysteme GmbH

house electricity distribution

connection to

public grid

Interfering

device

1. reconnect to
other phase

2. plug

filter

Sunny Boy

Control Light

Sunny Boy

Sunny Boy

Fig.7.7: Interference suppression at strong signal damping

Phase Coupler

If the communication is done with several phases, you have to consider a strong

damping resp. a significantly lower range for the data signal. If the string inverter,

contrary to our recommendation, is connected to another phase (e.g. L2) than Sunny

Boy Control Light (e.g. L1), the data transmission can only be successful if the

phases are coupled with sufficiently high frequency. In many households this is the

case by already installed three-phase current consumers (electric range, flow-type

heater and similar).

Additionally, the transmission line may be improved by the installation of a phase

coupler in the mains distribution. However, the communication over several phases

remains problematic:

Very long transmission paths result from the detour via the phase coupler, and by the

high-frequency coupling of the three phases the damping influence of electrical

devices connected to the other two phases is boosted.