The Sunny Boy Control Light constantly displays the percentage of correctly
transmitted packages. Only the last 20 packages are evaluated.
7.3 Technical Data
Supply voltage:
90 ... 260 V, 50 ... 60 Hz
Power
consumption:
4-6 W in operation (depends on the
amount of Sunny Boys to be managed)
3 W in standby mode
Carrier frequency for
Powerline communication:
132.45 kHz
Transmission
protocol:
compliant with DIN EN 50065 part 1
(VDE
0808
part
1)
Ambient temperature:
0 to 40 °C
Size:
229
x
126
x
46
mm
Display:
4
x
16
characters
Weight:
approx.
1250
g
Protection
type:
IP
40
Protection:
overload protection, 365 V / 90 mA
Connections:
•
Mains connection:
2 m 3-wire power cable,
with protective earth
•
PC (COM 2):
for connection to a PC or
for connection to an External Display