Transmission errors – SMA Sunny Boy Control Light User Manual

Page 72

Advertising
background image

Sunny Boy Control Light

Chapter 7: Appendix

SUNBCL-11:NE

- 72 -

SMA Regelsysteme GmbH

the following you will find an overview on how to manage problems you might have

with Powerline Communication.

7.2.1 Transmission

Errors

Reasons for communication interference can be:

•

Strong damping of the transmission signal

−

The transmission line is too long

−

The cabling layout is not suitable

•

Damping by other connected electrical devices

-

e.g. capacitors in fluorescent lamps

•

Insufficient phase coupling

−

The Sunny Boy Control Light and the Sunny Boy Inverters are

connected to different phases

−

Interference by other communication signals

−

Babyphone etc. in neighboring households

•

Failures due to different signals

−

Babyphone

−

Interphone

Each of the mentioned failure sources has effect on the quality of the transmission

line. However, this must not necessarily prevent Powerline Communication. In one

household mains the data transmission is possible without any problem via several

phases with 100 m total transmission distance, and in another installation there is a

strong interference on one line with 30 m on the same phase.