Connecting to an Upper Controller

System configuration requirements are listed below for connecting DriveWizard Plus to an upper
controller.

DriveWizard Plus

Ver. 3.00.0028 or later

Serial Communication
Interface

Ethernet, PCI bus

Engineering Tools
MPE720

MPE720 Ver. 6 (Ver. 6.30 or later)
MPE720 Ver. 6 Lite (Ver. 6.30 or later)
NOTE: For information on installation and other operations, refer to

Engineering Tool for MP2000 Series Machine Controller MPE
720 Version 6 USER’S MANUAL (manual No.: SIEP C880700
30).

Controller

Machine Controller MP2000 Series
MP2100/MP2100M, MP2200(CPU-03/04), MP2310, MP2300S, MP2400

Controller Software

Version

MP2100

Ver. 2.76 or later

MP2100M

*1

Ver. 2.76 or later

MP2200 CPU-03

*1

Ver. 2.76 or later

MP2200 CPU-04

*1

Ver. 2.76 or later

MP2310

*1

Ver. 2.76 or later

MP2300S

*1

Ver. 2.76 or later

MP2400

Ver. 2.76 or later

*1

Using the SVB-01 module requires that the SVB-01 software be Ver. 1.25 or later.


• Make sure the message communication function is enabled in the MECHATROLINK

master when connecting to an upper controller in addition to the following settings:

• Set the number of node address restarts to greater than 1.
• The number of nodes set for restart must be greater than the number of restarts

allowed:

(Number of restart nodes) – (Number of restarts allowed) > 1

Communications Option

SI-T3 Ver. 6104 or later
SI-T3/V Ver. 6104 or later

Drive

Set the MECHATROLINK communication speed to 10 Mbps (parameter F6-22 = 0).