6 test run, 1 manual operation, Test run – Yaskawa DriveWizard Plus User Manual

Page 170: Manual operation

Advertising
background image

170

4.6 Test Run

4.6.1 Manual Operation

The motor operates at the specific speed setting that has been entered. Manual Operation lets the user
check the direction of motor rotation and the speed setting without needing to use an upper controller.

Warning

Be sure to take proper precautions when performing a Manual Operation.
Read the manually thoroughly, paying particular attention to the following points:

Clear the area around the motor.

Clicking on the button marked “Run” will cause the motor to rotate at the designated speed.
Make sure proper precautions have been taken for the area surrounding the motor.

Make sure a Fast Stop has been set to one of the terminals.

If an error occurs with the PC or with this function while a Manual Run is being performed,
there is a chance the motor will continue rotating. Be sure that a Fast Stop or some other
type of emergency stop has been set to one of the external terminals in order to halt the
motor.

Do not edit parameter settings with any other software than DriveWizard Plus.

Use DriveWizard Plus only to edit parameter settings. Changing the frequency reference
units, for example, with the digital operator or some other device can cause the motor to
suddenly speed up and is extremely dangerous.

Check all parameter settings if a fault occurs.

This function switches the frequency reference selection, parameter settings, and Run
command selection over to MEMOBUS communications. Check PC and all function
settings if a communications fault occurs.

Always cycle power to the drive if a fault occurs.

This function works by assigning the frequency reference selection (comnet), parameter
settings, and Run command selection (comctrl) over to MEMOBUS communications.
Check PC and all function settings if a communications fault occurs, and cycle power to the
drive.

Extra Notes on Using Manual Operation

This function is for setting up the drive and performing a test run. It is strongly
recommended that the motor be fully decoupled from the load for proper setup.

NOTE: Manual Operation cannot be performed if the Baseblock command is currently enable via
one of the input terminals.
NOTE: To operate G5 manually, set the frequency references units to Hz (the default setting of
o1-03).