3 feed completed output signal – Yaskawa YASNAC PC NC I/O Signal Function Manual User Manual

Page 11

Advertising
background image

1 - 4

YASNAC PCNC I/O Signal Function Manual Chapter 1: Feed Function

1.3 Feed Completed Output Signal

For the execution of a part in the automatic mode, if an axis movement command isdesignated
with a M, S, T and/or B command in the same block, this output signal indicates the completion
of axis movement.

In a block where axis movement command is designated with a M, S, T and/or B command, if the
axis movement command has been completed even though a M, S, T and/or B command has not
been completed, the feed completed output DEN is “closed”.

When the FIN input is “opened” from the “closed” state after the closing if the feed completed
output DEN, the M, S, T and/or B command is assumed to have been executed and the feed
completed output DEN is “opened”.

Feed Completed Output Signal

DEN

#35374