Yaskawa YASNAC PC NC I/O Signal Function Manual User Manual
Page 50
Advertising
6 - 9
YASNAC PCNC I/O Signal Function Manual Chapter 6: Operation Support Functions
6.3 Manual Pulse/Step Multiplication Ratio Setting Input Signals
These signals determine axis feed amount per step when the PCNC is in the manual handle
or manual step feed mode.
Manual Handle/Step Multiplication Ratio Setting Table
Note: The status of signals is indicated by “0” or “1”.
0 : Open
1 : Closed
Manual Pulse/Step Multiplication Ratio Setting Input Signal
MP1 to MP4
#30025 TO #30027
MP1
MP2
MP4
Manual Step Feed
Manual Handle Feed
0
0
0
1 pulse/step
1
0
0
10 pulses/step
0
1
0
100 pulses/step
1
1
0
1000 pulses/step
100 pulses/step
0
0
1
10000 pulses/step
100 pulses/step
1
0
1
100000 pulses/step
100 pulses/step
0
1
1
Do not set
1
1
1
Advertising