6 - 9

YASNAC PCNC I/O Signal Function Manual Chapter 6: Operation Support Functions

6.3 Manual Pulse/Step Multiplication Ratio Setting Input Signals

These signals determine axis feed amount per step when the PCNC is in the manual handle
or manual step feed mode.

Manual Handle/Step Multiplication Ratio Setting Table

Note: The status of signals is indicated by “0” or “1”.

0 : Open
1 : Closed

Manual Pulse/Step Multiplication Ratio Setting Input Signal

MP1 to MP4

#30025 TO #30027

MP1

MP2

MP4

Manual Step Feed

Manual Handle Feed

0

0

0

1 pulse/step

1

0

0

10 pulses/step

0

1

0

100 pulses/step

1

1

0

1000 pulses/step

100 pulses/step

0

0

1

10000 pulses/step

100 pulses/step

1

0

1

100000 pulses/step

100 pulses/step

0

1

1

Do not set

1

1