YASNAC PCNC I/O Signal Function Manual Chapter 6: Operation Support Functions
6.2 Manual Jog Feedrate Selection Input Signal
These signals determine feedrate for manual jog feed operation.
The manual feedrate is also used for the feedrate when executing a part program in automatic
mode with the dry run function set ON.
Fig. 6.3 Manual Jog Feedrate Time Chart
Manual Jog Feedrate Table
Manual Jog Feedrate Selection Input Signal
JV1 to JV16
#30020 to #30024
JV1
JV2
JV4
JV8
JV16
Jog Feedrate (Manual Mode)
0
0
0
0
0
Feedrate set for pm2400
1
0
0
0
0
Feedrate set for pm2401
0
1
0
0
0
Feedrate set for pm2402
0
1
0
0
0
Feedrate set for pm2403
0
0
1
0
0
Feedrate set for pm2404
1
0
1
0
0
Feedrate set for pm2405
0
1
1
0
0
Feedrate set for pm2406
1
1
1
0
0
Feedrate set for pm2407
0
0
0
1
0
Feedrate set for pm2408
1
0
0
1
0
Feedrate set for pm2409
0
1
0
1
0
Feedrate set for pm2410
1
1
0
1
0
Feedrate set for pm2411
0
0
1
1
0
Feedrate set for pm2412
1
0
1
1
0
Feedrate set for pm2413
0
1
1
1
0
Feedrate set for pm2414
1
1
1
1
0
Feedrate set for pm2415
0
0
0
0
1
Feedrate set for pm2416
1
0
0
0
1
Feedrate set for pm2417
JOG mode
JV1 toJV16
Valid in this range