6 rapid traverse override input signal – Yaskawa YASNAC PC NC I/O Signal Function Manual User Manual

Page 15

Advertising
background image

1 - 8

YASNAC PCNC I/O Signal Function Manual Chapter 1: Feed Function

1.6 Rapid Traverse Override Input Signal

The rapid traverse override input signal determines the rapid traverse rate used in the execution
of positioning in automatic operation of CNC program, and also for manual rapid traverse
operation with the RT input “closed”.

IMPORTANT!

ROV4 can only be used when the extension override function (option) is selected.

Input Signals and Rapid Traverse Rates

Note 1:

The status of signals is indicated by “0” or “1”.

0: Open
1: Closed

Note 2:

Interpretation of the value set for ppm 2447, used for determining the traverse rate F

0

is indicated below.

pm2000 D3=0: The units of the value set forpm2447 are “mm/min.”.

pm2000 D3=1: The units of the value set forpm2447 are “%”.

Rapid Traverse Override Input Signal

ROV1 to ROV4

#30034 to #30036

Input Signal

Rapid Traverse Rates

ROV4

ROV2

ROV1

No. 1 Axis

No. 2 Axis

No. 3 Axis

No. 4 Axis

No. 5 Axis

0

1

1

Feedrate set
for pm2801

Feedrate set for
pm2802

Feedrate set for
pm2803

Feedrate set for
pm2804

Feedrate set for
pm2805

0

1

0

(Feedrate set for
pm2801) x 1/2

(Feedrate set for
pm2802) x 1/2

(Feedrate set for
pm2803) x 1/2

(Feedrate set for
pm2804) x 1/2

(Feedrate set for
pm2805) x 1/2

0

0

1

(Feedrate set for
pm2801) x 1/4

(Feedrate set for
pm2802) x 1/4

(Feedrate set for
pm2803) x 1/4

(Feedrate set for
pm2804) x 1/4

(Feedrate set for
pm2805) x 1/4

0

0

0

F

0

pm2801 to pm2805 x pm2447 (%), or traverse set for pm2447 (see Note 2)

1

0

0

F

0

pm2801 to pm2805 x pm2448 (%)

1

0

1

F

0

pm2801 to pm2805 x pm2449 (%)