YASNAC PCNC I/O Signal Function Manual Chapter 10: Safety and Maintenance Functions

10.6 Servo Alarm Output Signals

This output signal notifies the machine that an alarm has occurred when the PCNC detects any
of the following alarm factors:

• DSP Detecton Alarm

Overload (OL)
Runaway
PG open
Excessive deviation
Overspeed (OS)

• Monitor CPU Detection Alarm

Position error
ABSO error (encoder error)
Communication error

• I-AMP Detection Alarm

Overcurrent (OC)
MCCB trip
Regeneration error
Overvoltage (OV)
Undervoltage (UV)
Heat Sink overheat
Current command cable open
Open phase detection

10.7 Warning State Output Signal

The warning state output signal WARNS is “closed” when a minor error such as key operation
error or editing is detected.

It is “opened” by the successive key operation.

Servo Alarm Output Signal

SVALM

#35033

Warning State Output Signal

WARNS

#35004