Yaskawa YASNAC PC NC I/O Signal Function Manual User Manual

Page 49

Advertising
background image

6 - 8

YASNAC PCNC I/O Signal Function Manual Chapter 6: Operation Support Functions

Note: The status of signals is indicated by “0” or “1”.

0: Open
1: Closed

SUPPLEMENT

For a rotary axis, jog feedrate can be set 1/10 of the feedrate applied for a linear axis by setting the

parameter as indicated below.

pm2000 D7=0: Feedrate set for pm2400 to 2431 are applied to both linear and rotary axes.
pm2000 D7=1: For a rotary axis, 1/10 of the feedrate set for pm2400 to pm 2431 is applied.

0

1

0

0

1

Feedrate set for pm2418

1

1

0

0

1

Feedrate set for pm2419

0

0

1

0

1

Feedrate set for pm2420

1

0

1

0

1

Feedrate set for pm2421

0

1

1

0

1

Feedrate set for pm2422

1

1

1

0

1

Feedrate set for pm2423

0

0

0

1

1

Feedrate set for pm2424

1

0

0

1

1

Feedrate set for pm2425

0

1

0

1

1

Feedrate set for pm2426

1

1

0

1

1

Feedrate set for pm2427

0

0

1

1

1

Feedrate set for pm2428

1

0

1

1

1

Feedrate set for pm2429

0

1

1

1

1

Feedrate set for pm2430

1

1

1

1

1

Feedrate set for pm2431

JV1

JV2

JV4

JV8

JV16

Jog Feedrate (Manual Mode)