YASNAC PCNC I/O Signal Function Manual Chapter 10: Safety and Maintenance Functions

10.13 Stored Stroke Limit Check Input Signal

The stored stroke limit check input signals are used to select valid/invalid of the stored stroke
limit check for No.3 to No.5 ranges.

The setting for STSEL0 and STSEL1 is indicated below.

Note: The status of signals indicated by “0” or “1”.

0: Open
1 : Closed

Stored Stroke Limit

Check Input Signals

STSEL0

#30120

STSEL1

#30121

STSEL1 (#30121)

STSEL0 (#30120)

0

0

Stored stroke limit check is OFF for ranges No.3 to No.5

0

1

Stored stroke limit check is ON for range No.3

1

0

Stored stroke limit check is ON for range No.4

1

1

Stored stroke limit check is ON for range No.5