YASNAC PCNC I/O Signal Function Manual Chapter 10: Safety and Maintenance Functions
10.13 Stored Stroke Limit Check Input Signal
The stored stroke limit check input signals are used to select valid/invalid of the stored stroke
limit check for No.3 to No.5 ranges.
The setting for STSEL0 and STSEL1 is indicated below.
Note: The status of signals indicated by “0” or “1”.
0: Open
1 : Closed
Stored Stroke Limit
Check Input Signals
STSEL0
#30120
STSEL1
#30121
STSEL1 (#30121)
STSEL0 (#30120)
0
0
Stored stroke limit check is OFF for ranges No.3 to No.5
0
1
Stored stroke limit check is ON for range No.3
1
0
Stored stroke limit check is ON for range No.4
1
1
Stored stroke limit check is ON for range No.5