8 - 2

YASNAC PCNC I/O Signal Function Manual Chapter 8: Machine Support Functions

8.1 Internal Toggle Switch Monitor Output Signals

The status of the setting parameters can be output to the I/O variables to be read by the program-
mable controller. The relationship between the parameters and the addresses of the I/O variables
is as shown in the following tables.

Setting Parameter #0000 and the Output Signals

Setting Parameter #0001 and the Output Signals

Setting Parameter No.

Output Signal

#0000

D0: SBKT

Single block switch

#35150 (SETS SBK)

D1: MLKT

Machine lock switch

#35156 (SETS MLK)

D2: DRNT

Dry run switch

#35154 (SETS DRN)

D3: BDTT

Block delete switch

#35382 (SETS BDT)

D4: ABST

Manual absolute switch

#35151 (SETS ABS)

D5: AFLT

Auxiliary function lock switch

#35157 (SETS AFL)

D6: DLKT

Display lock switch

#35152 (SETS DLK)

D7: INHET

Edit lock switch

#35162 (SETS EDLK)

Setting Parameter No.

Output Signal

#0001

D0: OPST

Optional stop switch

#35383 (SETS OPT)

D1: STLKT

Start lock switch

#35176 (SETS STLK)

D2: ZNGT

Z-axis neglect switch

#35175 (SETS ZNG)