Yaskawa YASNAC PC NC I/O Signal Function Manual User Manual

Page 53

Advertising
background image

6 - 12

YASNAC PCNC I/O Signal Function Manual Chapter 6: Operation Support Functions

6.5 Single-Block Input Signal

This input signal is used to execute a part program block by block in automatic operation.
When the PCNC is in the automatic mode with SBK input signal “closed”, if automatic operation

is started, the PCNC executes one block of a part program and stops, the closes the STL (running,
#35370) output signal.

If the SBK input signal is “closed” during the execution of a part program, the PCNC stops after

the completion of the block presently being executed.

6.6 Manual Absolute Input Signal

(1) When the Absolute Input Signal is “Open”

Tool path of a part program executed continuously in automatic mode after manual interrup-
tion of axis movement is shifted by the manually moved distance.

Fig.6.5 Tool Path in Automatic Mode Operation

Fig.6.6 Tool Path after Manual Interruption (ABS Input Signal “Open”)

Single-Block Input Signal

SBK

#30060

Manual Absolute Input Signal

ABS

#30061

G90
G01

Z20.

000

F

∆∆

X20.

000

Y30.

000

X10.

000

Y40.

000

.

.

.

X20. 000
Y30. 000

{

X10. 000
Y20. 000

{

X10. 000
Y40. 000

{

X20. 000
Y30. 000

{

X10. 000
Y20. 000

{

X10. 000
Y40. 000

{

Manually operated axis movement