YASNAC PCNC I/O Signal Function Manual Chapter 10: Safety and Maintenance Functions

10.17 Servo Axis Load Monitor Output Signals

The load of servo axes is output in “%”.

Note: Output is given in binary and value “1” corresponds to 1%.

X-axis

Low byte ... #3740, High byte ... #3741

Y-axis

Low byte ... #3742, High byte ... #3743

Z-axis

Low byte ... #3744, High byte ... #3745

4th-axis

Low byte ... #3746, High byte ... #3747

5th-axis

Low byte ... #3748, High byte ... #3749