Network and module status leds at power-up, Network status led – Yaskawa DeviceNet Option Card CM05x User Manual

Page 61

Advertising
background image


Diagnostics and Troubleshooting 9-2

Network and Module Status LEDs at Power-Up


An LED test is performed at power-up. The following sequence should be observed:

• Module Status LED on GREEN for 0.25 seconds.
• Module Status LED on RED for 0.25 seconds.
• Module Status LED on GREEN for 0.25 seconds.
• Network Status LED on GREEN for 0.25 seconds.
• Network Status LED on RED for 0.25 seconds.

Network Status LED


The Network Status LED is located along the left edge of the Drive DeviceNet Option Board. The Network
Status LED is labeled “NS”. This bi-color (green/red) LED indicates the status of the communication link. The
following table defines the Network Status LED states.

LED state

Device State

Description

OFF

Not powered / Not On-line

Device is not on-line:
• The device has not completed the duplicate

MAC ID (node address) check

• The device may not be powered, look at the

Module Status LED.

Flashing

GREEN

On-line and not Connected

Device is on-line, but has no connections in the
established state:
• The device has passed the duplicate MAC ID

(node address) check, but has no established
connections to other nodes.

• For a Group 2 Only device (such as the Drive), it

means that this device is not allocated to a
Master device.

• For a UCMM capable device, it means that the

device has no established connections.

Solid

GREEN

On-line and Connected

Device is on-line and has connections in the
established state:
• For a Group 2 Only (such as the Drive), device it

means that the device is allocated to a Master

• For a UCMM capable device, it means that the

device has 1 or more established connections.

Flashing

RED

Connection Time-Out

One or more of the I/O Connections are in the
Timed-Out state. In the case of the Drive
DeviceNet Option Board, the Master device has
probably stopped polling the Drive Option Board.

Solid

RED

Critical Link Failure

Failed communication device. The device has
detected an error that has rendered it incapable of
communicating on the network:
• A duplicate MAC ID (node address) error was detected.
• A bus-off condition exists.

Note: The flash rate for the LED is approximately 1 flash per second. The LED is ON for

approximately 0.5 seconds and OFF for approximately 0.5 seconds.