Yaskawa DeviceNet Option Card CM05x User Manual

Page 74

Advertising
background image


DeviceNet Object Paths A-9

DeviceNet

Path

DeviceNet

Services

DeviceNet
Data Type

# of

Bytes

Description

Notes

41 / 0 / 1

GET

uint

2

Control Supervisor Object Revision

The DeviceNet specification revision of this Object.

41 / 0 / 6

-

uint

2

Max Class Attribute Number

The number of the last Class Attribute Implemented.

41 / 0 / 7

-

uint

2

Max Instance Attribute Number

The number of the last Instance Attribute Implemented.

41 / 1 / 1

GET

usint

1

Number of Control Attributes Supported

13

41 / 1 / 2

-

array

-

Control Supervisor Attribute List

-

41 / 1 / 3

GET/SET

bool

1

Run 1

1

Run forward command

41 / 1 / 4

GET/SET

bool

1

Run 2

1

Run reverse command

41 / 1 / 5

GET/SET

bool

1

Network Control Enable

0

Control from Local Option Board

1

Control from DeviceNet

41 / 1 / 6

GET

usint

1

State

0

Vendor Specific

1

Startup

2

Not

Ready

3

Ready

4

Enabled

5

Stopping

6

Fault

Stop

7

Faulted

41 / 1 / 7

GET

bool

1

Running 1

1

Drive is running in the forward direction

41 / 1 / 8

GET

bool

1

Running 2

1

Drive is running in the reverse direction

41 / 1 / 9

GET

bool

1

Ready

1

Drive is ready for operation

41/ 1 / 10

GET

bool

1

Faulted

1

Drive fault is active

41 / 1 / 11

GET

bool

1

Warning

1

Drive warning is active

41 / 1 / 12

GET/SET

bool

1

Fault Reset

1

Fault reset command

41 / 1 / 13

-

uint

2

Fault Code

See DeviceNet Specification.

41 / 1 / 14

-

uint

2

Warning Code

See DeviceNet Specification.

41 / 1 / 15

GET

bool

1

Network Control Enable Status

0

Control from Local Option Board

1

Control from DeviceNet

41 / 1 / 16

-

usint

1

DeviceNet Fault Mode

See DeviceNet Specification.

41 / 1 / 17

-

bool

1

Forced Fault

See DeviceNet Specification.

41 / 1 / 18

-

bool

1

Forced Fault Status

See DeviceNet Specification.

41 / 1 / 100

GET/SET

uint

2

Default Network Control (b1-02)

0

Digital Operator

1

Terminals

(default)

2

Modbus Serial Communication

3

Option Board (DeviceNet)

The Control Supervisor Class is required for compliance with the AC Drive Profile. Instance 1, Attributes 3, 7, 10 and 12 are required.
The DeviceNet Path is given in the format: Class ID / Instance ID / Attribute ID.
Attributes shown in GREY are not supported by the Drive DeviceNet Option Board.