Yaskawa drive u parameter class – Yaskawa DeviceNet Option Card CM05x User Manual

Page 80

Advertising
background image


DeviceNet Object Paths A-15

Yaskawa DRIVE U Parameter Class

DeviceNet

Path

DeviceNet

Services

DeviceNet
Data Type

# of

Bytes

Description

Notes

102 / 0 / 1

GET

uint

2

Yaskawa Object Revision

The DeviceNet specification revision of the Yaskawa Object.

102 / 0 / 2

GET

uint

2

Max Instance in this Class

1

102 / 0 / 6

-

uint

2

Max Class Attribute Number

The number of the last Class Attribute Implemented.

102 / 0 / 7

-

uint

2

Max Instance Attribute Number

The number of the last Instance Attribute Implemented.

102 / 1 / 1

GET

uint

2

Frequency Reference

U1-01 Speed Reference in Hz X 100 (6000 = 60.0 Hz).

102 / 1 / 2

GET

uint

2

Output Frequency

U1-02 See Drive Users Manual.

102 / 1 / 3

GET

uint

2

Output Current

U1-03 See Drive Users Manual.

102 / 1 / 4

GET

uint

2

Control Method

U1-04 See Drive Users Manual.

102 / 1 / 5

GET

uint

2

Motor Speed

U1-05 See Drive Users Manual (F7 and G7 only).

102 / 1 / 6

GET

uint

2

Output Voltage

U1-06 See Drive Users Manual.

102 / 1 / 7

GET

uint

2

DC Bus Voltage

U1-07 See Drive Users Manual.

102 / 1 / 8

GET

uint

2

Output Power

U1-08 See Drive Users Manual.

102 / 1 / 9

GET

uint

2

Torque Reference

U1-09 See Drive Users Manual (F7 and G7 only).

102 / 1 / 10

GET

uint

2

Input Terminal Status

U1-10 See Drive Users Manual.

102 / 1 / 11

GET

uint

2

Output Terminal Status

U1-11 See Drive Users Manual.

102 / 1 / 12

GET

uint

2

Operation Status

U1-12 See Drive Users Manual.

102 / 1 / 13

GET

uint

2

Elapsed Time

U1-13 See Drive Users Manual.

102 / 1 / 14

GET

uint

2

Software No. (FLASH ID No.)

U1-14 See Drive Users Manual.

102 / 1 / 15

GET

uint

2

Control Circuit Terminal A1 Input Level

U1-15 See Drive Users Manual.

102 / 1 / 16

GET

uint

2

Control Circuit Terminal A2 Input Level

U1-16 See Drive Users Manual.

102 / 1 / 17

GET

uint

2

Control Circuit Terminal A3 Input Level

U1-17 See Drive Users Manual (F7 and G7 only).

102 / 1 / 18

GET

uint

2

Motor Secondary Current (Iq)

U1-18 See Drive Users Manual.

102 / 1 / 19

GET

uint

2

Motor Excitation Current (Id)

U1-19 See Drive Users Manual (F7 and G7 only).

102 / 1 / 20

GET

uint

2

Output Frequency after Soft-start

U1-20 See Drive Users Manual.

102 / 1 / 21

GET

uint

2

Automatic Speed Regulator (ASR) Input

U1-21 See Drive Users Manual (F7 and G7 only).

102 / 1 / 22

GET

uint

2

Automatic Speed Regulator (ASR) Output

U1-22 See Drive Users Manual (F7 and G7 only).

102 / 1 / 23

GET

uint

2

Speed Deviation Regulator Input

U1-23 See Drive Users Manual (F7 and G7 only).

102 / 1 / 24

GET

uint

2

PID Feedback Amount

U1-24 See Drive Users Manual.

102 / 1 / 25

GET

uint

2

DI-16H2 Input Status

U1-25 See Drive Users Manual (F7 and G7 only).

102 / 1 / 26

GET

uint

2

Output Voltage Reference Vq

U1-26 See Drive Users Manual (F7 and G7 only).

102 / 1 / 27

GET

uint

2

Output Voltage Reference Vd

U1-27 See Drive Users Manual (F7 and G7 only).

102 / 1 / 28

GET

uint

2

Software No. CPU

U1-28 See Drive Users Manual.

The DeviceNet Path is given in the format: Class ID / Instance ID / Attribute ID.
Attributes shown in GREY are not supported by the DRIVE DeviceNet Option Board.

Advertising