6.4.1. Measurement procedure and results of "2-W"and "3-W" mode

1. Select "2-W" or "3-W" Earth measurement mode by means of the F1 key.
2. Connect the Black, Red, Green and Blue cables to the corresponding input terminals

of the instrument B1, B2, B3, B4 (see possible connections in the following pictures).


B2

B3

B4

B1

I1

1

3
N

Connection for 3 point Earth resistance

measurement

B2

B3

B4

B1

I1

1

1

3

3

N

N

Transf

Connection for 2 point Earth Resistance

measurement

B2

B3

B4

B1

I1

1

3
N

Connection for measuring the resistance between an extraneous conductive part and the earth system