Start Here

MVI56E-MCMR ♦ ControlLogix Platform

User Manual

Modbus Communication Module with Reduced Data Block

Page 28 of 225

ProSoft Technology, Inc.

May 13, 2014

2 Select the 1756-M

ODULE

(G

ENERIC

1756

M

ODULE

)

from the list and click OK.

This action opens the N

EW

M

ODULE

dialog box.

3 Set the Module Properties values as follows:

Parameter

Value

Name

Enter a module identification string. The recommended value is
MCMR, as this name will be linked automatically with the MSG
paths, irrespective of the slot location.

Description

Enter a description for the module. Example: ProSoft
communication module for Modbus Serial protocol
communications.

Comm Format

Select D

ATA

-INT (*Very Important*)

Slot

Enter the slot number in the rack where the MVI56E-MCMR
module is to be installed.

Input Assembly Instance

1

Input Size

42

Output Assembly Instance

2

Output Size

42

Configuration Assembly Instance 4

Configuration Size

0

Advertising