ProSoft Technology PTQ-AFC User Manual

Page 103

Advertising
background image

PTQ-AFC ♦ Modicon Quantum Platform

Quick Start

Liquid and Gas Flow Computer for Hydrocarbon Products

User Manual

ProSoft Technology, Inc.

Page 103 of 259

June 23, 2011

Number of Words per
Archive

Number of Daily Archives

Number of Hourly Archives

10

106 daily archives

144 hourly archives

20

53 daily archives

72 hourly archives

30

35 daily archives

48 hourly archives

40

26 daily archives

36 hourly archives

You may also configure the accumulator type for each archive. You must
configure one of the following options:

Mass

Energy (Gas product only)

Net

Volume

Gross

Volume

Gross

Standard

Water Volume (Liquid product only)

The following topics show the default archive structure when you configure a new
meter. You can edit this structure according to your own requirements.

6.11.8 Extended Archives

This feature is only supported on firmware versions 2.01.000 or newer, and
requires a Compact Flash card to be installed.
The module supports the extended archive feature that allows you to configure
more archives than the regular 35 daily archives and 48 hourly archives. The
module supports the following number of extended archives:

Daily

Archives

Hourly Archives

Max Number of Archives

350 (version 2.04 and earlier)
1440 (version 2.05 and newer)

1260 (version 2.04 and earlier)
1440 (version 2.05 and newer)

Refer to Extended File Size entry on the Archive Configuration window for
more information.

Note: The maximum number of extended archives is not dependent on the number of words per
archive. Extended archives are stored on a Compact Flash card which must be installed for
Extended Archive configuration to be effective.

Retrieving Extended Archives
The module implements an easy way to retrieve extended archives from the
Modbus database. To learn how to retrieve extended archives, click Archive
Config on the Meter Configuration dialog box, and then click Modbus Addresses.
For each archive file the module reserves a block of 50 Input registers to hold the
"selected Archive", as listed in the following table.

Meter

Daily Archive Start
(Input Register)

Daily Archive End
(Input Register)

Hourly Archive Start
(Input Register)

Hourly Archive End

(Input Register)

1

60000 60049

60050

60099

2

60100 60149

60150

60199

3

60200 60249

60250

60299

4

60300 60349

60350

60399

5

60400 60449

60450

60499