Meter 1:

Tag M01

Wallclock 0000/00/00.00:00:00

Barometric pressurekPaa 101,325

Viscosity 0,010268

Orifice/pipe geometric parameters

Orifice plate Meter tube

Temperature 68 68

Diameter 1 2

Coefficient 9,25E-06 0,0000062

______________________________________________________________________

Scan 1

Temperature (Floating point) 15

Pressure (Floating point) 1000

Dif. pressure (Floating point) 22

Temperature (°F) 15

Pressure (psig) 1000

Dif. pressure (hw) 22

Scan period (second) 0,48

Specific gravity 0,7404104

Fpv 0

Compressibility flowing 0,9051347

Compressibility reference 0,9989105

Diameter at T tube 1,999343

Diameter at T orifice 0,9995098

Velocity of approach factor ev 1,032773

Pressure extension xt 149,4683

Coefficient of discharge cd 0,6042569

Expansion factor y 0,9997441

Composition factor 0,2728558

Mass flow Qh 2280,571

Orifice characterization error 0

Analysis characterization error 0

AGA8 calculation error 0

Gross accu. - totalizer (x f3) 3408

Gross accu. - residue (x f3) 0,2047686

Gross increment (x f3) 6,442598E-02

Gross flow rate (x f3/h) 483,1948

Net accu. - totalizer (x f3) 390113

Net accu. - residue (x f3) 0,8464546

Net increment (x f3) 5,3664

Net flow rate (x f3/h) 40248

Mass accu. - totalizer (x lb) 22094

Mass accu. - residue (x lb) 0,5677222

Mass increment (x lb) 0,3040761

Mass flow rate (x lb/h) 2280,571

Analysis components

C1 methane 0,55

N2 nitrogen 0,45

CO2 carbon dioxide 0

C2 ethane 0

C3 propane 0

H2O water 0

H2S hydrogen sulphide 0

H2 hydrogen 0

CO carbon monoxide 0