ProSoft Technology PTQ-AFC User Manual

Page 105

Advertising
background image

PTQ-AFC ♦ Modicon Quantum Platform

Quick Start

Liquid and Gas Flow Computer for Hydrocarbon Products

User Manual

ProSoft Technology, Inc.

Page 105 of 259

June 23, 2011

Meter

Open Daily Archive
Select Address

Open Hourly Archive
Select Address

1

8300 8301

2

10300 10301

3

12300 12301

4

14300 14301

5

16300 16301

6

18300 18301

7

20300 20301

8

22300 22301

9

24300 24301

10

26300 26301

11

28300 28301

12

30300 30301

13

32300 32301

14

34300 34301

15

36300 36301

16

38300 38301

Note: Meters 9 through 16 are only available for the PTQ-AFC and MVI56-AFC modules.

Use the following procedure to retrieve extended archives:
1

Copy the archive age to the correct Open Archive Select register.

2

Read the archive data from the 60000-range input addresses.

Example
To read Meter 2 Hourly Archive Number 277:
1

Write a value of 277 to Modbus Holding Register 10301.

2

Read the archive record data starting at input register 60150.

Note: This procedure can also be used to retrieve regular archives.