O2 oxygen 0

iC4 iso-butane 0

nC4 normal butane 0

iC5 iso-pentane 0

nC5 normal pentane 0

C6 hexane 0

C7 heptane 0

C8 octane 0

C9 nonane 0

C10 decane 0

He helium 0

Ar argon 0

neoC5 neopentane 0

Ux user1 0

Uy user2 0

AFC-56(16) Audit Date: 16-09-2002 16:18:08

Site Name: MVI Flow Station

Project: AFC

_______________________________________________________________________

Meter 1:

Tag M01

Wallclock 0000/00/00.00:00:00

Barometric pressurekPaa 101,325

Viscosity 0,010268

Orifice/pipe geometric parameters

Orifice plate Meter tube

Temperature 68 68

Diameter 1 2

Coefficient 9,25E-06 0,0000062

_______________________________________________________________________

Scan 2

Temperature (Floating point) 15

Pressure (Floating point) 1000

Dif. pressure (Floating point) 22

Temperature (°F) 15

Pressure (psig) 1000

Dif. pressure (hw) 22

Scan period (second) 0,495

Specific gravity 0,7404104

Fpv 0

Compressibility flowing 0,9051347

Compressibility reference 0,9989105

Diameter at T tube 1,999343

Diameter at T orifice 0,9995098

Velocity of approach factor ev 1,032773

Pressure extension xt 149,4683

Coefficient of discharge cd 0,6042569

Expansion factor y 0,9997441

Composition factor 0,2728558

Mass flow Qh 2280,571

Orifice characterization error 0

Analysis characterization error 0

AGA8 calculation error 0