ProSoft Technology PTQ-AFC User Manual

Page 184

Advertising
background image

Backplane Communication

PTQ-AFC ♦ Modicon Quantum Platform

User Manual

Liquid and Gas Flow Computer for Hydrocarbon Products

Page 184 of 259

ProSoft Technology, Inc.

June 23, 2011

9.3 Sample

Files

Refer to the product web page for the sample files as follows:

File

Platform

PTQ-AFC CONCEPT SAMPLE.zip

Quantum/Concept

PTQ-AFC UNITY SAMPLE.zip

Unity

9.3.1 Concept Sample Files

You may refer to the sample file PTQ-AFC CONCEPT SAMPLE.zip available in
the web site to install and configure the module. The following files are part of the
ZIP file:

Description

File Name

Data Types

PTQAFCDATATYPES.DTY

Variables

PTQVAR_.TXT

Templates

*.RDF

Sample Structured Text Program

WALLCLOCK.ST

PTQAFC.PRZ

Sample archived program

Memory Usage Spreadsheet

samplememoryusage.xls

PTQ-AFC sample configuration file

Quantum(16).afc

Data Types
You can move the PTQAFCDATATYPES.DTY file to the \DFB folder in order to
use predefined data types for the application.
For example, the data type definition file defines METER_DIFF_GAS_VAR data
type to be used to store the variables for differential meters using gas product as
follows:

TYPE

METER_DIFF_GAS_VAR:

STRUCT

Reserved: INT;

Temperature: REAL ;

Pressure: REAL;

DifferentialPressure: REAL;

END_STRUCT;

END_TYPE

Advertising