Meter Proving

PTQ-AFC ♦ Modicon Quantum Platform

User Manual

Liquid and Gas Flow Computer for Hydrocarbon Products

Page 152 of 259

ProSoft Technology, Inc.

June 23, 2011

8.2.2 Meter

Proving

Alarms

These alarms are transient and any one might exist only for a single scan, so
they might be missed when viewing this register directly. However, alarms are
also accumulated into the results database, so alarms that have occurred during
any run may be viewed by inspecting that database.

To Check for Alarms

1

Activate Meter Monitor dialog box

2

Select M

ETER

to be proved

3

Click on the

[R

EAD

]

button

Note: Verify that the meter is not generating any alarms. Meter proving cannot proceed while any
alarm is displayed.

This is accomplished by providing P

ROCESS

P

ARAMETER

values that are within

the range of the Process Input Scaling Dialog box.

There are two sources of alarms:
1

From the meter, which occur whether or not a prove is in progress. These are
illustrated above.

2

From the prove, and there are 2 kinds:

a) Variation Limit Alarms
b) Prove Calculation Alarms


Note: Any alarm will always make a run not able to be selected.