ProSoft Technology PTQ-AFC User Manual

Page 118

Advertising
background image

Quick Start

PTQ-AFC ♦ Modicon Quantum Platform

User Manual

Liquid and Gas Flow Computer for Hydrocarbon Products

Page 118 of 259

ProSoft Technology, Inc.

June 23, 2011

6.12.6 Loggable events

The tables below give full details of all events that are recorded in the Event Log.
For the Special events (page 118), columns are:

Tag

Numeric value that identifies the event.

Rkv

Effect on archives and accumulator resets (see next).

Description

Lists:
The event name, identifying its triggering condition.
Contents and meaning of the old and new value fields.
Relevant additional information.

For the Datum Point (page 121, page 119, page 124) events, columns are:

Grup

Group code.

Sbgp

Subgroup code.

Item

Item code.

Dtyp

Datum type code (mnemonic).

Rkv

Effect on archives and accumulator resets (see next).

Datum point

The corresponding writable Modbus point.

In these tables, the "Rkv" columns specify how archives and accumulator resets
are scheduled upon occurrence of the corresponding loggable events.
Column values are:

Value

Meaning

*

Upon this event archives and resets are scheduled according to the
configured "event" Archive Options, provided that the applicable
meter(s) is(are) enabled. Applicable meters depend upon the event
class:
(a) Special (non-meter-specific) and Site Datum Point events:
All meters.
(b) Meter events (including meter-specific Specials):
The addressed meter.
(c) Stream events:
The addressed meter, provided that the addressed stream is active.
Scheduled archives are always written before completing any change to
data or module state implied by the event; this ensures that the data
contributing to an archive is limited to that which was available before
the event.

-

This event has no effect on archives and resets.

(n)

Upon this event archives and resets are scheduled as for "*", modified
by the conditions and actions given in "Note (n)" in "Rkv" notes (page
125).

6.12.7 Special events

Tag

Rkv Description

0

- Never

Used

Value: Always 0.
Notes: This entry in the Event Log has never been written.
The number of such entries starts at 1999 upon cold start and
decreases as events are written until none remain, after which oldest
events are overwritten with new ones.

Advertising
This manual is related to the following products: