ProSoft Technology PTQ-AFC User Manual

Page 96

Advertising
background image

Quick Start

PTQ-AFC ♦ Modicon Quantum Platform

User Manual

Liquid and Gas Flow Computer for Hydrocarbon Products

Page 96 of 259

ProSoft Technology, Inc.

June 23, 2011

6.11 Archives

6.11.1 Archive Overview

An archive is a set of data that records relevant process values that occurred
during a certain period of time (per meter channel). The archives are
automatically generated by the module and no further action is required. The
process values can include:

Net flow rate (average)

Total

accumulator

Temperature

(average)

Alarms occurred during the period

The process values will depend on the meter type and product group as listed
later in this section.
Each archive contains two values that informs the period of time about that
archive:

opening timestamp = starting date and time for archive

closing timestamp = ending date and time for archive

The example described in this chapter is of the default archive configuration as is
present for a newly allocated meter. Version 2.01 of the firmware and AFC
Manager allows the default configuration to be changed. Refer to Editing the
Archive Structure.

6.11.2 Archive Generation

The archives can be generated during one of the following situations:

Upon period end

Upon

event

Upon processor command

Advertising
This manual is related to the following products: