4.6.4 SNTP/NTP

Status

The following SNTP/NTP Status diagnostics data is available from the gateway

Value

Description

Time from SNTP/NTP server

This shows the time retrieved from the SNTP/NTP server.

Poll Count

The following Poll Count diagnostics data is available from the gateway

Value

Description

Clock Update Count

This displays the number of times the gateway’s clock has been
updated.

Error Count

This is the number of unsuccessful times the gateway has
attempted to reach the SNTP/ NTP Server.

Configuration Settings

The following Configuration Settings diagnostic data is available from the
gateway

Value

Description

Update rate in Minutes

How frequently the time is synchronized via SNTP/NTP. This is a
configured value that is set on the Gateway Configuration
window, in the SNTP/NTP Update Time field.

Server Address

The IP address or domain name for the SNTP/NTP server. This is
a configured value that is set on the Gateway Configuration
window, in the SNTP/NTP Address field.

Driver Status

The following Configuration Settings diagnostic data is available from the
gateway

Value

Description

Status

This is the result of the latest poll. Values are OK or Error
retrieving time from SNTP/NTP server.

Poll Count

This is the number of update attempts (at the configured
frequency) since startup (unsigned long rolls over at 4 billion
plus). If Poll Count is zero (before first attempt, or configured
update time is 0 for never poll) Status is OK.