Ebsu maintain firmware screen, Ebsu maintain firmware update screen – HP INTEGRITY RX3600 User Manual

Page 114

Advertising
background image

7.

Use the down arrow key to scroll down to the Smart Array Controller item in the list.

8.

Press Enter to display detailed information about the device.

Figure 3-27 EBSU Maintain Firmware Screen

EBSU displays the firmware update screen for the selected device.

The version number in the first column (ROM Firmware Version) is the one currently
installed on your system.

The version number in the second column (ROM Version on Disk) is the one available
on your Smart Setup media.

Figure 3-28 EBSU Maintain Firmware Update Screen

9.

Compare the two version numbers and perform one of the following options:

If the number in the first column is the same or higher than the number in the second
column, your installed firmware is current. You do not need to update the firmware
for this device! You can exit EBSU and quit this procedure.

If the number in the first column is less than the number in the second column, your
installed firmware is older than the version on your Smart Setup media. You must
update the firmware for this device! Proceed to Step 9 and continue from there.