Safety Information

Use care to prevent injury and equipment damage removing and replacing server components.
Voltages can be present within the server. Many assemblies are sensitive to damage by electrostatic
discharge (ESD).

Follow the safety conventions listed below to ensure safe handling of components, to prevent
injury, and to prevent damage to the server:

When removing or installing any server component, follow the instructions provided in this
guide.

If installing a hot-swappable or hot-pluggable component when power is applied (fans are
running), reinstall the server cover immediately to prevent overheating.

If installing a hot-pluggable component, complete the required software intervention prior
to removing the component.

If installing an assembly that is neither hot-swappable nor hot-pluggable, disconnect the
power cable from the external server power receptacle.

WARNING!

Ensure that the system is powered off and all power sources are disconnected

from the server prior to removing or installing server hardware (unless you are removing
or installing a hot-swappable or hot-pluggable component).

Voltages are present at various locations within the server whenever an ac power source is
connected. This voltage is present even when the main power switch is turned off.

Failure to observe this warning can result in personal injury or damage to equipment.

Do not wear loose clothing that can snag or catch on the server or on other items.

Do not wear clothing subject to static charge buildup, such as wool or synthetic materials.

If installing an internal assembly, wear an antistatic wrist strap and use a grounding mat,
such as those included in the Electrically Conductive Field Service Grounding Kit (HP
9300-1155).

Handle accessory boards and components by the edges only. Do not touch any metal-edge
connectors or any electrical components on accessory boards.

HP Integrity rx3600 Component Classification

The server components are classified into three major categories:

“Hot-Swappable Components”

“Hot-Pluggable Components”

“Cold-Swappable Components”

A brief explanation of each category and the classifications for the server components follow.

Hot-Swappable Components

A component is defined as hot-swappable if you can remove it from the chassis while the server
remains operational. Hot-swappable components require no software intervention prior to
removing the component.

NOTE:

Hot-swappable components are marked with red touch points.

The following are hot-swappable components:

Fan units

Power supplies