Configuring the array, C-10, Ebsu maintain firmware update screen – HP INTEGRITY RX3600 User Manual

Page 312

Advertising
background image

The version number in the first column (ROM Firmware Version) is the one currently
installed on your system.

The version number in the second column (ROM Version on Disk) is the one available
on your Smart Setup media.

Figure C-10 EBSU Maintain Firmware Update Screen

9.

Compare the two version numbers and perform one of the following options:

If the number in the first column is the same or higher than the number in the second
column, your installed firmware is current. You do not need to update the firmware
for this device! You can exit EBSU and quit this procedure.

If the number in the first column is less than the number in the second column, your
installed firmware is older than the version on your Smart Setup media. You must
update the firmware for this device! Proceed to Step 9 and continue from there.

NOTE:

The utility does not allow you to flash the firmware if the installed version is the

same or higher than the version on the Smart Setup media.

10. Use the tab key to scroll down into the Device section and highlight the device name.
11. Press Enter to select the device (this puts an “X” inside the box on the left side of the device

name).

12. Use the tab key to move to the OK selection and press Enter.

]The firmware update begins and proceeds automatically to completion.

Configuring the Array

provides two utilities for manually configuring an array on a Smart Array controller:

ORCA

, a simple ROM-based configuration utility.

Array Configuration Utility (ACU), a versatile, browser-based utility that provides maximum
control over configuration parameters

312