Powering on the server, Powering on the server using the ilo 2 mp, Powering on the server manually – HP INTEGRITY RX3600 User Manual

Page 94: Power states, Table 3-14

Advertising
background image

Table 3-14 Power States

DC Voltage
Applied

AC Voltage
Applied

Powered On With the iLO 2 MP PC
Command; or Front Panel Power Button
Pressed

Power Cable
Plugged into
Receptacle

Power States

No

Yes

No

Yes

Standby power

Yes

Yes

Yes

Yes

Full power

No

No

No

No

Off

NOTE:

If the power restore feature is set to Always On through the iLO 2 MP PR command,

the server can automatically power on to the full power state.

Powering On the Server

Power on the server to full power using the following methods:

iLO 2 MP PC command

Power button

Powering On the Server Using the iLO 2 MP

NOTE:

If the power restore feature is set to Always On through the iLO 2 MP PR command,

the server can automatically power on to the full power state.

To power on the server using the iLO 2 MP, follow these steps:

1.

Plug all power cables into the receptacles on the rear panel of the server.

2.

Initiate a console session and access the MP Main Menu.

3.

Enter CM to enable command mode.

4.

Enter PC to use the remote power control command.

5.

Enter ON to power on the server, and enter YES when prompted to confirm the action.

6.

Start the operating system. For more information see the operating system documentation.

Powering On the Server Manually

NOTE:

If the power restore feature is set to Always On through the iLO 2 MP PR command,

the server may automatically power on to the full power state.

To manually power on the server, follow these steps:

1.

Plug all power cables into the receptacles on the rear panel of the server.

2.

Press the power button to start the server.

94

Installing the System