Replacing the system battery, Battery location on i/o board, Figure 6-26 – HP INTEGRITY RX3600 User Manual

Page 231

Advertising
background image

Figure 6-26 Battery Location on I/O Board

1

2

3

4

4

3

1

Core I/O Board Slot

System Battery

TPM

2

I/O VRM

Replacing the System Battery

1.

Insert the replacement battery into the socket on the I/O board assembly.

CAUTION:

You must remove the I/O board assembly to service the system battery. The

removal and replacement of the I/O board assembly occurs through the rear of the rack for
rack-installed servers. Carefully follow the removal and replacement procedures; you must
perform several tasks with the server extended out the front of the rack. See

“Removing and

Replacing the I/O Board Assembly” (page 225)

for complete instructions.

NOTE:

The positive terminal of the battery is designated by the + sign. Install the battery

with the + sign facing up.

2.

Replace the I/O board assembly. See

“Replacing the I/O Board Assembly” (page 228)

.

3.

Reconnect the power cables and power on the server. See

“Powering On the Server”

(page 94)

.

4.

Reset the server date and time using the EFI date and time commands.

Removing and Replacing the System Battery

231