Installing memory, Dimm memory carrier loading examples – HP INTEGRITY RX3600 User Manual

Page 212

Advertising
background image

IMPORTANT:

The number in parenthesis indicates the order in which the quads are loaded.

Table 6-7 24-DIMM Memory Carrier Loading Examples

Memory Carrier Side 1

Memory Carrier Side 0

Quad Slot IDs

Quad Number

Example 1

2 GB (2)

2 GB (1)

0A 0B 0C 0D

0

1 GB (4)

1 GB (3)

1A 1B 1C 1D

1

512 MB (6)

512 MB (5)

2A 2B 2C 2D

2

Example 2

1 GB (2)

2 GB (1)

0A 0B 0C 0D

0

1 GB (3)

512 MB (4)

1A 1B 1C 1D

1

512 MB (5)

2A 2B 2C 2D

2

Example 3

1 GB (2)

2 GB (1)

0A 0B 0C 0D

0

512 MB (3)

1A 1B 1C 1D

1

512 MB (4)

2A 2B 2C 2D

2

Example 4

512 MB (2)

2 GB (1)

0A 0B 0C 0D

0

512 MB (3)

512 MB (5)

1A 1B 1C 1D

1

512 MB (4)

512 MB (6)

2A; 2B 2C 2D

2

Installing Memory

IMPORTANT:

You must pull the ac power plugs on the server every time you modify the

DIMMs. If you do not pull the ac power plugs, the system does not display the correct DIMM
information.

To install memory, follow these steps:

1.

Power off the server and disconnect the power cables. See

“Powering Off the Server”

(page 95)

.

2.

If rack installed, slide the server out from the rack until it stops. See

“Extending the Server

from the Rack” (page 180)

.

3.

Unlatch the cover release lever on the top cover and remove the memory carrier assembly
cover. See

“Removing the Memory Carrier Assembly Cover” (page 183)

.

NOTE:

You do not need to fully remove the top cover to service this component; however,

the top cover release lever must be open.

4.

Remove the memory carrier assembly. See

“Removing the Memory Carrier Assembly”

(page 204)

.

212

Removing and Replacing Server Components