NOTE:

When the memory carrier assembly cover is open or removed, the chassis fan units

increase to high speed to assist cooling. When the top cover is replaced at the end of the operation,
the chassis fans return to normal speed.

Removing the Memory Carrier Assembly Cover

To remove the memory carrier assembly cover, follow these steps:

1.

If rack installed, slide the server out from the rack until it stops. See

“Extending the Server

from the Rack” (page 180)

.

NOTE:

You do not need to extend the server completely out of the rack to remove the

memory carrier.

2.

Unlock the cover release lever by turning the cam approximately 90 degrees counterclockwise.

3.

Pull up on the cover release lever to disengage the top cover and memory carrier assembly
cover from the chassis (

Figure 6-3

).

4.

Slide the memory carrier assembly cover toward the left side of the server to free it from the
center of the chassis, and lift the cover off of the chassis (

Figure 6-4

).

Figure 6-4 Removing and Replacing the Memory Carrier Assembly Cover

Memory Carrier
Assembly Cover

Top Cover

Cover Release
Lever (Latch/Unlatch)

Replacing the Memory Carrier Assembly Cover

To replace the memory carrier assembly cover, follow these steps:

Removing and Replacing the Memory Carrier Assembly Cover

183